Online Monitoring highlights deterioration in desalter performance & Direct linkage to upset overhead conditions 

  1. Home
  2. Online Salt Analyzer

Contact Customer Service

GIVE US A CALL

Some products and services might not apply to all countries.
For more information, please contact your Ecolab representative, complete the Contact form, e-mail or call Customer Service at the corresponding address or phone number below.

Ecolab Latin America Headquarters
2901 SW 149th Ave., Suite 300, Miramar, FL 33027

Latin America Customer Service
Email: CustomerServiceLA@ecolab.com

Country Phone Number
 Antigua  268-562-8741
 Argentina 
 0800-999-8313 
 Bahamas 
 242-377-5121 
 Barbados   246-428-1602 
 Brazil   0800-704-1409 
 Chile  600-241-6600 
 Colombia    57-1-414-2394 Ext. 100 - 102 - 110 
 Costa Rica   506-2436-3900 
 Ecuador   593-2-247-7-528
 El Salvador   503-2221-0069 
 Guatemala   502-2315-1200
 Honduras   504-2559-1756 
 Jamaica   876-926-0750 
 Mexico   1-800-326-2000 
 Nicaragua   505-2244-4470 
 Panama   507-232 8534 
 Peru   51-1-717-6174 
 Puerto Rico  787-796-1290 
 Saint Lucia  758-451-6900 
 Trinidad   868-225-4116
 Venezuela   58-212-263-7878 
Tell Us About Yourself
Where Are you Located?
How Can We Reach You?
How Can We Help You?

Data Privacy Concerns? See our Privacy Policy.

 

The Situation

Effectively managing desalters and overhead corrosion control programs can be a challenge; the combination of frequent crude changes with significant batch to batch variation make good control difficult. Coupled with process variability and the typical low frequency of measurements, the reality is that good control is difficult to achieve and there is total ignorance about what is happening in the intervening periods between measurements.

90% of Overhead Corrosion can happen in as little as 10% of the time.

the solution

A Gulf Coast Refiner installed the Nalco Champion Online Salt Analyzer (OSA) at the desalted crude outlet of a crude unit, complimenting the 3D TRASARTM Technology for Crude Overhead Systems (3DTCOS) that was already installed on the unit. Both inorganic and organic chlorine were detected by the OSA, providing real-time chlorine measurements, ensuring that upsets can be detected quickly and mitigating actions taken whilst enabling ongoing desalter performance to meet critical KPI’s.

the results

The refiner operated in total ignorance between measurements and was often unaware of the impact even the smallest upset can cause. Shortly after commissioning the OSA, the refinery experienced an issue with one of the two fired heaters and as a consequence, had to reduce feed rates. Upon reducing feed rate, the OSA began to show a sharp increase in salt exiting the desalter with the 3DTCOS showing an increase in overhead chlorides.

The online analyzers alerted Operations to the increases, and it was quickly determined that the reduction in feed rate resulted in a reduction in the mix valve dP that impacted desalting efficiency. Once this was recognized, the mix valve dP was increase and the salt in crude and overhead chlorides reduced almost immediately, returning to typical levels.